EasyManua.ls Logo

Leadshine ELD2-RS70 Series - Upper Computer Operation

Leadshine ELD2-RS70 Series
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual for ELD2 Servo
www.leadshine.com
83
positioning related data of path-0
17 4D the CRC verification code, do not have to directly input, click the corresponding send area verification
button automatically generated
The final analysis is as follows: speed is 1000r/min, acceleration and deceleration time is 100ms,
Speed mode
7.5 Upper computer operation
Upper computer is used for drive parameter setting and save, steps for debugging is:
1. Three-loop control parameters. According to the position mode debugging method.
2. Set the work mode to be PR modePr0.01=0),Internal SERVO-enabled Pr4.00=383),set the distribution
of IO register P4.0-P4.13) Confirm the running direction and so on.
3. Setting up the PR basic control parameters through upper computer's " Pr-MODE " interface. Include:
trigger setting, software limit, JOG function, homing function, e-stop function and so on.
4. Setting up the PR positioning path parameters through upper computer's " Pr-MODE " interface, include:

Table of Contents