76 CN4093 Application Guide for ENOS 8.4
Updating Software on vLAG Switches
WhenupdatingthesoftwareandbootimagesforswitchesconfiguredwithvLAG,
first:
MakesurethatthespanningtreerootswitchisnotoneofthevLAGswitches
Shutdownofportsshoulddoneundertheportconfiguration
Followtheshutdownorderoftheports
a. ISLlinks
b. vLAGlinks
c. vLAGhealthcheck(MGTport)
Thenfollowthisproceduretoupdatethesoftwa reonvLAGswitches:
1. OnSwitch2(theoriginalSecondaryswitch),shutdownalllinksISL,vLAGlinks,
andvLAGHC.Thisisequivalenttopoweringoff
Switch2.
AllthetrafficwillfailovertoSwitch1(theoriginalPrimaryswitch.).
AftertheshutdownoflinksonSwitch2,therewillbeNStrafficlossofaround
~0.16seconds.
2. UpgradeSwitch2withthenewimage.UseFTP,STFP,orTFTPtocopythenew
ENOSandbootimagesontotheswitch.Formoredetails,see“LoadingNew
SoftwaretoYour
Switch”onpage 74.
AfterSwitch2comesup,vLAGHCwillbeupandvLAGmismatchwillhappen
withvLAGportsdown(sinceitisstillSecondary).
ThetrafficwillstillbeforwardingviaSwitch1(theoriginalPrimaryswitch).
3. OnSwitch1(theoriginalPrimaryswitch),shutdownalllinksISL, vLAGlinks,and
vLAGHC.ThisisequivalenttopoweringoffSwitch1(theoriginalPrimaryswitch)
AllthetrafficwillfailovertoSwitch2,whichwillassumethevLAGoperation
roleofPrimary.
AfterallthelinksareuponSwitch2,therewillbeNStrafficlossofaround~70
secondsduetospanningtreesreconverging.
4. UpgradeSwitch1(theoriginalPrimaryswitchwiththenewENOSimage.Use
FTP,STFP,orTFTPtocopythenewENOSand bootimagesonto
theswitch.For
moredetails,see“LoadingNewSoftwaretoYourSwitch”onpage 74.
AfterSwitch1comesup,vLAGHC,ISL,andvLAGlinkswillbeup,andSwitch
1willassumethevLAGoperationroleofSecondary.
AllthetrafficwillnowfollowthehashandloadbalancesettingsbetweenSwitch
1andSwitch2.
TherewillbeNStrafficlossofaround~0.05seconds.
5. ChangetheoperationalroleofthevLAGswitchestomatchthefinaltopologyby
reloadingSwitch2.
TherewillbeNStrafficlossofaround~0.102seconds.

Table of Contents

Other manuals for Lenovo Flex System Fabric CN4093

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenovo Flex System Fabric CN4093 and is the answer not in the manual?

Lenovo Flex System Fabric CN4093 Specifications

General IconGeneral
BrandLenovo
ModelFlex System Fabric CN4093
CategorySwitch
LanguageEnglish

Related product manuals