76 CN4093 Application Guide for ENOS 8.4
Updating Software on vLAG Switches
WhenupdatingthesoftwareandbootimagesforswitchesconfiguredwithvLAG,
first:
MakesurethatthespanningtreerootswitchisnotoneofthevLAGswitches
Shutdownofportsshoulddoneundertheportconfiguration
Followtheshutdownorderoftheports
a. ISLlinks
b. vLAGlinks
c. vLAGhealthcheck(MGTport)
Thenfollowthisproceduretoupdatethesoftwa reonvLAGswitches:
1. OnSwitch2(theoriginalSecondaryswitch),shutdownalllinksISL,vLAGlinks,
andvLAGHC.Thisisequivalenttopoweringoff
Switch2.
AllthetrafficwillfailovertoSwitch1(theoriginalPrimaryswitch.).
AftertheshutdownoflinksonSwitch2,therewillbeN‐Strafficlossofaround
~0.16seconds.
2. UpgradeSwitch2withthenewimage.UseFTP,STFP,orTFTPtocopythenew
ENOSandbootimagesontotheswitch.Formoredetails,see“LoadingNew
SoftwaretoYour
Switch”onpage 74.
AfterSwitch2comesup,vLAGHCwillbeupandvLAGmismatchwillhappen
withvLAGportsdown(sinceitisstillSecondary).
ThetrafficwillstillbeforwardingviaSwitch1(theoriginalPrimaryswitch).
3. OnSwitch1(theoriginalPrimaryswitch),shutdownalllinksISL, vLAGlinks,and
vLAGHC.ThisisequivalenttopoweringoffSwitch1(theoriginalPrimaryswitch)
AllthetrafficwillfailovertoSwitch2,whichwillassumethevLAGoperation
roleofPrimary.
AfterallthelinksareuponSwitch2,therewillbeN‐Strafficlossofaround~70
secondsduetospanningtreesreconverging.
4. UpgradeSwitch1(theoriginalPrimaryswitchwiththenewENOSimage.Use
FTP,STFP,orTFTPtocopythenewENOSand bootimagesonto
theswitch.For
moredetails,see“LoadingNewSoftwaretoYourSwitch”onpage 74.
AfterSwitch1comesup,vLAGHC,ISL,andvLAGlinkswillbeup,andSwitch
1willassumethevLAGoperationroleofSecondary.
AllthetrafficwillnowfollowthehashandloadbalancesettingsbetweenSwitch
1andSwitch2.
TherewillbeN‐Strafficlossofaround~0.05seconds.
5. ChangetheoperationalroleofthevLAGswitchestomatchthefinaltopologyby
reloadingSwitch2.