Figure 101. Memory module installation
a. Open the memory module connector retaining clips. If a memory module is already installed in
the connector, remove it.
b. Align the keys on the memory module that you are installing with the connector; then, insert the
memory module.
c. Firmly press both ends of the memory module straight down into the connector until the
retaining clips snap into the locked position.
Step 2. If you are installing additional memory modules, do so now.
After you install a memory module:
1. Install the upper compute system board or compute system board filler, if it was removed. See “Install a
compute system board” on page 128.
2. Install the compute tray where the compute system board is installed. See “Install the compute tray (fully
removed)” on page 125.
3. Install the front cover. See “Install the front cover” on page 139
Riser replacement
Risers are in the I/O tray that is accessed from the rear of the server. The removal and installation procedures
for each riser type are different and are described in the following topics:
Riser for PCIe adapters 1 through 4 (left riser): see “Remove the riser for slots 1 through 4 (left riser)” on
page 170 and “Install the riser for slots 1 through 4 (left riser)” on page 176
Note: There is no riser for PCIe adapters 5 through 7, the ML2 x16 network adapter (slot 8), and the LOM
adapter (slot 9); these adapters install directly in the I/O tray.
Riser for PCIe adapters 10 through 15 (right riser): see “Remove the riser for slots 10 through 15 (right
riser)” on page 171 and “Install the riser for slots 10 through 15 (right riser)” on page 177