Index table
14
Appendix
14.2
l
14.2-12
EDSPM-TXXX-3.0-04/2004
Index ImportantPossible settingsName
SelectionLenze
I300F
h
*
Config
analog/counter
module 15
00000000
h
{1
h
} FFFFFFFF
h
Configures analog or counter module in
slot 15
Index is only a vailable in the modular
E 12.3-1
E 12.4-1
E 12.5-1
1 0
h
system
.
E 12.6-1
2 0
h
3 0
h
4 0
h
I3010
h
*
Config
analog/counter
module 16
00000000
h
{1
h
} FFFFFFFF
h
Configures analog or counter module in
slot 16
Index is only a vailable in the modular
E 12.3-1
E 12.4-1
E 12.5-1
1 0
h
system
.
E 12.6-1
2 0
h
3 0
h
4 0
h
I6000
h
Digital input 0 {1} 255
Display only E 9.11-4
1 Module 1
digital input status
2 Module 2
... ...
32 Module 32
I6002
h
*
Change polarity
digital input
0 {1} 255
Inverts digital input signals E 12.2-1
1 Module 1 0
2 Module 2 0
... ... ...
32 Module 32 0
I6200
h
Digital output 0 {1} 255
Display only E 9.11-4
1 Module 1
digital output status
2 Module 2
... ...
32 Module 32
I6202
h
Change polarity
digital output
0 {1} 255
Inverts digital output signals E 12.2-1
1 Module 1 0
2 Module 2 0
... ... ...
32 Module 32 0
I6206
h
Error mode digital
output
0 {1} 255 Configures digital output monitoring
For the compact system, only index I6206
h
,
subindex 1 is available
E 9.10-2
0 All digi tal outputs retain the last status output.
255 Reaction from I6207
h
In I6207
h
, the response can be configured
individually for each digital output
1 Module 1 0
2 Module 2 0
... ... ...
32 Module 32 0