EasyManua.ls Logo

Lenze L-force 8400 BaseLine D - Page 193

Lenze L-force 8400 BaseLine D
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 03.00 - DMS EN 5.0 - 07/2009 L 193
8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00155
C00155
Parameter | Name:
C00155 | Status word 2
Data type: UNSIGNED_16
Index: 24420
d
= 5F64
h
Bit coded device status word 2
Display range (min. hex value | max. hex value)
0x0000 0xFFFF
Value is bit-coded: Info
Bit 0 Fail Fail
Bit 1 M_max Maximum torque
Bit 2 I_max Maximum current
Bit 3 PowerDisabled Power switched off
Bit 4 Ready Ready
Bit 5 ControllerInhibit Controller is inhibited
Bit 6 Trouble Fault
Bit 7 InitState InitState
Bit 8 CwCcw CW/CCW rotation
Bit 9 reserved
Bit 10 SafeTorqueOff Safe torque off
Bit 11 reserved
Bit 12 reserved
Bit 13 reserved
Bit 14 Quick stop Quick stop is active
Bit 15 MotorIdent Motor parameter identification active
; Read access Write access CINH PLC STOP ; No transfer COM MOT