8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00228
200 L Firmware 03.00 - DMS EN 5.0 - 07/2009
C00228
C00231
C00234
C00235
C00236
Parameter | Name:
C00228 | L_PCTRL_1: deceleration time
Data type: UNSIGNED_32
Index: 24347
d
= 5F1B
h
From version 03.00.00
FB L_PCTRL_1
: Deceleration time for the output value of the PID process controller
Setting range (min. value | unit | max. value) Lenze setting
0.0 s 999.9 0.1 s
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000
Parameter | Name:
C00231 | L_PCTRL_1: Operating range
Data type: INTEGER_16
Index: 24344
d
= 5F18
h
From version 03.00.00
FB L_PCTRL_1
: Operating range for the PID process controller
Setting range (min. value | unit | max. value)
0.0 % 199.9
Subcodes Lenze setting Info
C00231/1 199.9 % L_PCTRL_1: Pos. maximum
C00231/2 0.0 % L_PCTRL_1: Pos. minimum
C00231/3 0.0 % L_PCTRL_1: Neg. minimum
C00231/4 199.9 % L_PCTRL_1: Neg. maximum
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00234 | Oscillation damping influence
Data type: UNSIGNED_16
Index: 24341
d
= 5F15
h
Setting range (min. value | unit | max. value) Lenze setting
0 % 250 5%
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00235 | Filter time - oscill. damping
Data type: UNSIGNED_8
Index: 24340
d
= 5F14
h
This code is used internally by the controller and must not be overwritten by the user!
Parameter | Name:
C00236 | Oscill. damping - field weakening
Data type: UNSIGNED_8
Index: 24339
d
= 5F13
h
This code is used internally by the controller and must not be overwritten by the user!

Table of Contents