Firmware 03.00 - DMS EN 5.0 - 07/2009 L 201
8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00242
C00242
C00243
C00244
C00245
Parameter | Name:
C00242 | L_PCTRL_1: operating mode
Data type: UNSIGNED_8
Index: 24333
d
= 5F0D
h
From version 03.00.00
FB L_PCTRL_1
: Selection of the operating mode
• Depending on the selection, the blue switches in the displayed signal flow are set accordingly in the Engineer on
the Application parameter tab in the Overview Signal flow Process controller dialog level.
Selection list (Lenze setting printed in bold) Info
0Off The input setpoint nNSet_a is output without any chang-
es at the nOut_a output.
1 Additive + feedforward control nNSet_a and nAct_a are used as PID input values. The in-
put setpoint nNSet_a is added to the value output by the
PID element.
2 PID as setpoint generator nSet_a and nAct_a are used as PID input values. The
nNSet_a input is not considered.
3 PID setpoint from L_NSet_1 nNSet_a and nAct_a are used as PID input values. The
nSet_a is not considered.
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00243 | L_PCTRL_1: Acceleration time influence
Data type: UNSIGNED_32
Index: 24332
d
= 5F0C
h
From version 03.00.00
FB L_PCTRL_1
: Acceleration time for showing the PID output value
Setting range (min. value | unit | max. value) Lenze setting
0.0 s 999.9 5.0 s
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000
Parameter | Name:
C00244 | L_PCTRL_1: Deceleration time influence
Data type: UNSIGNED_32
Index: 24331
d
= 5F0B
h
From version 03.00.00
FB L_PCTRL_1
: Deceleration time for masking out the PID output value
Setting range (min. value | unit | max. value) Lenze setting
0.0 s 999.9 5.0 s
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000
Parameter | Name:
C00245 | L_PCTRL_1: PID output value
Data type: INTEGER_16
Index: 24330
d
= 5F0A
h
From version 03.00.00
FB L_PCTRL_1
: Display of the output value of the PID process controller
Display range (min. value | unit | max. value)
-199.9 % 199.9
; Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100