Firmware 03.00 - DMS EN 5.0 - 07/2009 L 29
8400 BaseLine D | Software Manual
Commissioning
Test commissioning
4. Set keypad control
5. Enable the controller:
Set terminal X4/RFR to HIGH potential (X4/12I).
6. Use the keypad to change the motor velocity or
the motor speed by selecting different fixed setpoints:
7. Save the settings with mains failure protection by entering the value "1" in code C002,
subcode 7.
• Select menu -3- (quick commissioning with integrated keypad)
• Press "Enter" key
•Set code C007
• Press "Enter" key
• Set value "20"
• Press "Enter" key
Internal Keypad Code Subcode Motor speed
C728 3 CCW rotation:
-199.9 % ..... 0 (from C011
)
CW rotation:
0 ... +199.9 % (from C011
)
C051 - Observe
• the actual speed value:
C051
• appearing messages
Diagnostics
( 23)
-0-
_
-1-
5 sec.
_
_
_
....
`
_
-2-
Status
Password
Menu
Code Subcode
Action
`
_
C051
C728
199.9
`
....
_
c003
-199.9