Firmware 03.00 - DMS EN 5.0 - 07/2009 L 63
8400 BaseLine D | Software Manual
Drive control (DCTRL)
System block "LS_DriveInterface"
Status word output
[4-2] Status word of the controller
[4-3] Extended status word of the controller
bCwCcw True Motor rotates in CCW direction
bNactCompare For open-loop operation: Speed setpoint = comparison value C024
For closed-loop operation: Actual speed value = comparison value
C024
Bit Function INFO
0 FreeStatusBit0
1 PowerDisabled Inverter control is inhibited (IMP)
2 FreeStatusBit2 Function depends on the application
selected
3 FreeStatusBit3
4 FreeStatusBit4
5 FreeStatusBit5
6 ActSpeedIsZero Actual speed = 0
7 ControllerInhibit Controller inhibit is active
8 StatusCodeBit0 Status ID (bit-coded)
9StatusCodeBit1
10 StatusCodeBit2
11 StatusCodeBit3
12 Warning
13 Trouble
14 FreeStatusBit14 Function depends on the application
selected
15 FreeStatusBit15
Identifier
DIS code | data type
Value/meaning
Bit Function INFO
0Fail
1M_max
2I_max

Table of Contents