PROFIsafe and PROFINET
Leuze electronic GmbH + Co. KG RSL 420P 113
Byte in
non-safe
telegram
Byte in
module
Bit Data
type
Signal name Value ‘0‘ Value ‘1‘ Safe Description
19 2 0…3 Bit B-PAIR-
SEL3
N Third selected field
pair B (numbers
1-10); superim-
posed field
4 Reserve1
5 Reserve2
6 Bit B-FP-SEL-1 OFF SE-
LECTED
N Defined field pair
selected - protec-
tive function B
7 Bit B-FP-SEL-2 OFF SE-
LECTED
N Defined field pair
selected - protec-
tive function B
11.5.9
Module [M7] – PROTECTIVE_FUNCTION_A_VIOLATION
• Module ID:0x00000002
• Submodule ID:0x00000007
If the protective field or warning field is interrupted for protective function A, the module indicates the angle
and distance of the first interruption. The first interruption corresponds to the first interruption in the direc-
tion of rotation.
Input data structure module – PROTECTIVE_FUNCTION_A_VIOLATION
Byte in
non-safe
telegram
Byte in
module
Bit Data
type
Signal name Value ‘0‘ Value ‘1‘ Safe Description
20 0 0…15 Int16 A-PF-VIO-
ANGLE
N Angle of the first
beam with protec-
tive field violation
in the direction of
rotation for protec-
tive field
-135°…+135°
22 2 0…15 uInt16 A-PF-VIO-
RADIUS
N Distance of the
first beam with pro-
tective field viola-
tion in the direction
of rotation for pro-
tective field
0mm…8250mm
24 4 0…15 Int16 A-WF-VIO-
ANGLE
N Angle of the first
beam with warning
field violation in the
direction of rotation
for warning field
-135°…+135°
26 6 0…15 uInt16 A-WF-VIO-
RADIUS
N Distance of the
first beam with
warning field viola-
tion in the direction
of rotation for
warning field
0mm…20000m
m