Electrical connection
Leuze electronic GmbH + Co. KG RSL 420P 71
8.5 Connection unit CU400P-AIDA
1
2 31
All dimensions in mm
1 AIDA sockets, PROFINET, push-pull, 5-pin, voltage supply
2 AIDA socket, PROFINET, RJ45 push-pull, 8-pin, Ethernet, input
3 AIDA socket, PROFINET, RJ45 push-pull, 8-pin, Ethernet, output
Fig.8.7: Device with connection unit CU400P-AIDA
Voltage supply
The safety sensor is supplied with voltage via two 5-pin PROFINET AIDA push/pull connections for copper
cables. The scanner is supplied from mains L1/N1.
1 5
Fig.8.8: Pin assignment PROFINET AIDA push-pull, 5-pin
Tab.8.5: Pin assignment for voltage supply
PIN Signal Comment
1 L1 24VDC (US1+)
2 N1 0VDC (US1-)
3 L2 24VDC (US2+)
4 N2 0VDC (US2-)
5 GND/shield It is also possible to operate the device with unshielded interconnection cables.
The use of shielded interconnection cables is, however, recommended.
The current load of the connections must not exceed 16 A/pin.
NOTICE
Ä Lay the cables for the linear topology and the tap in the PROFINET controller in such a way
that short circuits are prevented.