Mounting
Leuze electronic GmbH + Co. KG RSL 420P 52
NOTICE
With protective field boundaries <200mm, object detection may be restricted owing to the mea-
surement error.
Ä When defining the protective field, take into account the additional distance Z
sm
to the pro-
tective field contour (see chapter 7.2 "Stationary danger zone guarding").
Configure the protective field so that the safety-related switching outputs are switched off from every
accessible point with sufficient minimum distanceD.
Determine the start-up/restart operating mode required for the application.
If you are using start and/or restart interlock, determine the position for the reset button.
Many safety-relevant parameters are preset for each application in the configuration and diagnostics
software. Use these preset values where possible.
Determine the conditions for the field pair changeover and the sequence of the field pair changeover.
Ä Create a record document for the device configuration and protective field dimensioning.
The document must be signed by the person responsible for the configuration.
Include this document with the machine documentation.
Ä Mark the protective field boundaries on the floor.
You can easily test the safety sensor along this marking.
After mounting, you can electrically connect (see chapter 8 "Electrical connection"), start up, align (see
chapter 10 "Starting up the device"), and test (see chapter 12 "Testing") the safety sensor.
7.1.4
Mounting examples
5
4
,
6
54,6
1
2
3
all dimensions in mm
1 Safety sensor
2 Column
3 BT856M mounting bracket
Fig.7.4: Example: mounting on a post