PROFIsafe and PROFINET
Leuze electronic GmbH + Co. KG RSL 420P 120
Byte in
non-safe
telegram
Byte in
mod-
ule
Bit Data
type
Signal name Value
‘0‘
Value
‘1‘
Safe Description
3 3 0 Bit EA1 N Status of local out-
put1 (currently not
implemented)
1 Bit EA2 N Status of local out-
put2 (currently not
implemented)
2…7 Bit Reserve
4 4 0 Bit A-WF-VIO AS-
SIGNE
D
FREE N Status of active
warning field - pro-
tective functionA
1 Bit A-PF-VIO AS-
SIGNE
D
FREE N Status of active
protective field -
protective func-
tionA
2…3 Bit Reserve
4 Bit B-WF-VIO AS-
SIGNE
D
FREE N Status of active
warning field - pro-
tective functionB
5 Bit B-PF-VIO AS-
SIGNE
D
FREE N Status of active
protective field -
protective func-
tionB
6…7 Bit Reserve
5 5 0 Bit A-RES-WF OFF AC-
TIVE
N Start/restart active
(warning fieldA)
1 Bit A-RES OFF AC-
TIVE
N Start/restart active
(protective fieldA)
2…3 Bit Reserve
4 Bit B-RES-WF OFF AC-
TIVE
N Start/restart active
(warning fieldB)
5 Bit B-RES OFF AC-
TIVE
N Start/restart active
(protective fieldB)
6…7 Bit Reserve
11.5.14
Module [M13] – SYSTEM_DATA
Module ID:0x00000004
Submodule ID:0x0000000D
Description
The module contains the current data of the internal spirit level for aligning the device.
The module also contains the data of the inside temperature and the applied supply voltage.

Table of Contents