Functions
Leuze electronic GmbH + Co. KG RSL 420P 35
Access level Functions
Engineer In addition to the functions of the Expert, full access to all user-relevant func-
tions and parameters:
Create and change a safety configuration:
• Save configuration data to file
• Change all parameters of configuration
• Reset safety sensor to default values
• Define and change protective/warning fields
• Set reference contour in protective field
• Print and delete protective/warning fields
• Load protective/warning field data from file
• Save protective/warning field data
• Transfer protective/warning field data from the PC to the safety sensor
• Change passwords
NOTICE
The software saves individual passwords in the connected safety sensor, thereby ensuring that
only authorized users can change the existing configuration.
Determining access level
When creating a user in the user management via Tools > User management in the FDT frame menu, se-
lect the access level for the user. In the user management you can also create and change passwords for
the users.
Using the device manager (DTM) you can change the access level of the user (see chapter 4.5.1 "Select-
ing access level").
Ä Click in the DTM menu bar on the [Change access level]button (
).
5.2 Function modes of safety sensor
You configure the functions of the safety sensor in configuration projects with the help of the configuration
and diagnostics software. In each configuration project you determine the protective function and the con-
figurable field pairs via the selected function mode.
You select the function mode of the safety sensor in the software device manager (DTM) with CONFIGU-
RATION > Device function (see chapter 9 "Configuring the safety sensor").
You use the protective function to define the criteria for switching off the safety-related switching outputs
(Parameters for protective function).
The changeover-capable protective and warning field pairs for the selected function mode are defined in
the configuration banks, e.g. CONFIGURATION > Protective functionA > BankA1.
Overview of the function modes
Tab.5.2: Function modes
Function mode Field pairs (FP)
Protective fields (PF)
Warning fields (WF)
Field pair activation
One protective function 1FP / 1PF + 1WF Fixed selection of one field pair
5FP / 5PF + 5WF Selection by signal input:
• Overlapped monitoring
10FP / 10PF + 10WF Selection by signal input:
• Fixed changeover moment