5.11 5.11 Connection light barrier 1Connection light barrier 1
Withrstcommissioningandafteraresetthelightbarrieris
automatically detected and programmed. If no light barrier
system is connected, the input is requested every time the
power is switched on again until a light barrier system has
been detected. With a subsequent change, the respective
system must be selected via a parameter setting in the input
operating mode.
In the case of light barriers with a test function, this must be
set manually.
Ô “10.2Inputoperatingmode”
Light barrier 4-wire NC
withouttesting parameterLIGHTBARR1=MOD3
withtesting parameterLIGHTBARR1=MOD5
OUT
-
+
-
+
NC
1
2
3
4
5
6
7
8
9
12
11
10
X4
R
T
5.11 / 1
Light barrier Marantec Legden 2-wire
withtesting parameterLIGHTBARR1=MOD1
2
1
2
1
1
2
3
4
5
6
7
8
9
12
11
10
X4
R
T
5.11 / 2
Light barrier 3 wire NPN
withouttesting parameterLIGHTBARR1=MOD2
withtesting parameterLIGHTBARR1=MOD4
OUT
-
+
-
+
NPN
1
2
3
4
5
6
7
8
9
12
11
10
X4
R
T
5.11 / 3
Light barrier 3 wire PNP
withouttesting parameterLIGHTBARR1=MOD3
withtesting parameterLIGHTBARR1=MOD5
OUT
-
+
-
+
PNP
1
2
3
4
5
6
7
8
9
12
11
10
X4
R
T
5.11 / 4
Legend:
R Receiver
T Transmitter
NOTE:
All light barriers are active in the UP or DOWN direction
depending on the setting.
Ô “10.2Inputoperatingmode”(ParameterLBFUNC1)