8 – Control CS 320 / Rev.D 1.01 Control CS 320 / Rev.D 1.01 – 9
5.4 5.4 Mains voltage selectionMains voltage selection
The position of the bridge connector to X21 must be adjusted
to the supply voltage and motor voltage.
N
L3
L2
L1
X1
X21
3
400 V / 50 Hz
/ N / PE
F2.3
F2.2
F2.1
3
230 V / 50 Hz
/ PE
F2.1
F2.2
F2.3
1
230 V / 50 Hz
/ N / PE
F2.1
F2.2
F2.3
5.4 / 1
N
L3
L2
L1
X1
X21
3
400 V / 50 Hz
/ N / PE
F2.3
F2.2
F2.1
N
L3
L2
L1
X1
X21
3
230 V / 50 Hz
/ PE
F2.1
F2.2
F2.3
1
230 V / 50 Hz
/ N / PE
F2.1
F2.2
F2.3
5.4 / 2
N
L3
L2
L1
X1
X21
3
400 V / 50 Hz
/ N / PE
F2.3
F2.2
F2.1
3
230 V / 50 Hz
/ PE
F2.1
F2.2
F2.3
L
N
X1
X21
1
230 V / 50 Hz
/ N / PE
F2.1
F2.2
F2.3
5.4 / 3
5.5 5.5 Supply to external devices Supply to external devices
(only with 400 V / 3-phase connection)(only with 400 V / 3-phase connection)
TheCS320has2separatevoltagesuppliesforexternal
components, such as signal devices, light barriers, etc.
X19 230V/1~
X4 24V-DC
N
L3
L2
L1
X1
X21
X19
3
400 V / 50 Hz
max. 1A
230V-AC
max. 500mA
24V-DC
/ N / PE
X4
1
2
3
4
5
6
7
8
9
12
11
10
F1
-
+
L
N
5.5 / 1
NOTE:
Use of the connection X19 is only possible with a supply with
400V / N / 3~.
The connection X19 is protected by the fuse element F1
(max.1A/T).
Installation