20 – Control CS 320 / Rev.D 1.01 Control CS 320 / Rev.D 1.01 – 21
5.14 5.14 Safety input per EN 12453Safety input per EN 12453
Increased requirements on the fail-safety of the slip door
switch have been part of EN 12453 since 2001. With
EN12453:2017increasedsafetyrequirements(PLc,Cat.2)
also apply, for example to slack rope switches and switches
of fall protection systems, including the transmission and
processing of the signal.
With the setting MOD2 the programmable INPUT 2 allows
the evaluation of these components, which all work with an
internal resistance value of 8.2 kOhm. If a fault occurs in one
of the components, the system can no longer be operated and
the message ERROR STOP appears on the display.
1 – 4 components on a 8.2 kOhm basis can be linked
according to the following wiring diagrams. It does not matter
which of the respective switches represents the components
1 - 4 here.
* optionally
CHECK
The tolerance of the individual resistance values must not
exceed max. 1%.
Connection 4 components
1
2
3
4
5
6
7
8
9
12
11
10
X4
8,2 k Ω8,2 k Ω8,2 k Ω
8,2 k Ω
1
2
3
4
5.14 / 1
Connection 3 components
1
2
3
4
5
6
7
8
9
12
11
10
X4
8,2 k Ω8,2 k Ω8,2 k Ω
1
2
3
*
8,2 k Ω8,2 k Ω
1
2
8,2 k Ω
3
5.14 / 2
Connection 2 components
1
2
3
4
5
6
7
8
9
12
11
10
X4
8,2 k Ω8,2 k Ω
1
2
8,2 k Ω
1
*
8,2 k Ω
2
5.14 / 3
Connection 1 component
1
2
3
4
5
6
7
8
9
12
11
10
X4
8,2 k Ω
1
5.14 / 4
Installation