8 – Control CS 320 / Rev.D 1.01 Control CS 320 / Rev.D 1.01 – 9
EN
5.6 5.6 Connection of electronic limit position Connection of electronic limit position
system absolute value encoder (AWG)system absolute value encoder (AWG)
5.6 / 1
A
B
A: Absolute value encoder plug
B: AWG plug-in terminal
Connector strip X11 (on connector A)
4 7
grey yellow
5 8
green pink
6 9
white brown
5.6 / 2
Cables with either numbered or
coloured wires are used for the AWG,
depending on the drive:
4 (grey): Safety chain input
5 (green): RS 485 B
6 (white): GND
7 (yellow): RS485 A
8 (pink): Safety circuit output
9 (brown): 12V DC
Connector strip B (only absolute value encoder)
5.6 / 3
C: Thermal element in the drive
D: Emergency manual actuation (emergency crank or
emergency chain)
NOTE:
In order to satisfy the requirements of EN 12453:2017 the
electronic end position system must comply as a minimum
withPL“c”withamin.category2perENISO13849-1.
In order to satisfy this requirement, it is only permissible to
use an absolute value encoder from Marantec Legden
(art. no. 97957) as an electronic end position system.
5.7 5.7 Mechanical limit switch (MEC) connectionMechanical limit switch (MEC) connection
Alternatively to the absolute value encoder as an electronic
system, it is also possible to connect a mechanical cam limit
switch and evaluate this.
WithrstcommissioningandafteraRESET,theconnected
limit position system is automatically detected. With a
subsequent change, the respective limit position system must
be selected via a parameter setting in the INPUT operating
mode.
Series STA, MDF05, MTZ05
5.7 / 1
S1
S2
S3
S4
S5
S6