5. Installation
5.1 5.1 Safety instructions for installationSafety instructions for installation
WARNING!
Life-threatening danger due to electric shock!
Before performing wiring work, always disconnect the
Before performing wiring work, always disconnect the
system from the power supply. Make sure that the power
system from the power supply. Make sure that the power
supply remains disconnected during wiring work.
supply remains disconnected during wiring work.
ATTENTION!
Property damage due to improper installation of
the controller!
In order to avoid damage to the controller, observe the
following points:
Onlyqualiedandtrainedelectriciansmayworkon
electrical systems.
Switch off the power supply to the system, check that it
is de-energised and safeguard against reconnection.
Mains cables and control cables must be routed separa-
tely.
The line types and cross-sections must be selected in
accordancewiththevalidspecications.
It is essential to observe the local protective regulations.
Observethespecicationsofthedoormanufacturerfor
installation.
The following points must be correct to guarantee
fault-free functioning:
The door is installed, fully functional and designed for
power-driven operation.
Thegearmotoristtedandreadyforoperation.
Thecommandandsafetydevicesarettedandreadyfor
operation.
ThecontrolhousingwiththeCS320controlleristted.
Observe the valid standards and regulations!
REFERENCE
The instructions from the respective manufacturer must be
observed for the installation of the door, the gear motor and
the command and safety devices.
5.2 5.2 Mains connectionMains connection
Prerequisites
The following points must be correct to guarantee the
function of the controller:
The mains voltage must correspond with the information
on the type plate.
The mains voltage must correspond with the voltage of the
drive.
In the case of three-phase power, this must have a
clockwiserotatingeld.
Withaxedconnection,anall-polemainswitchmustbe
used.
With three-phase power, only triple block circuit breakers of
type C (max. 16 A) shall be used.
ATTENTION!
Malfunctions due to improper installation of the
controller!
Beforeswitchingonthecontrollerforthersttimebut
after all of the wiring has been completed, it is necessary
to check all motor connections on the motor and controller
sides. All control voltage inputs are galvanically separated
from the supply.
The control and load lines of the connected drives must be
double-insulated along their entire route.
Detailed wiring diagram of mains connection and
motor connection (400 V / 3-phase)
B2
B1
W
V
U
N
L3
L2
L1
X1
X21
F2.1
F2.2
F2.3
F1
X19
X11
X18
X2
M
3
3
400 V / 50 Hz
/ N / PE
5.2 / 1