Control CS 320 / Rev.D 1.01 – 35
10.2 10.2 Input operating modeInput operating mode
Function Description
Adjustment
options
Factory setting
DEUTSCH Selection of the menu language.
Only with LCD monitor:
The menu language can also be selected during the initialisation phase (during
rstcommissioningorafterareset).Thefactorypre-setmenulanguage(ENGLISH)
appearshereforapprox.60secondsasashingtextinthedisplay.Atthistimeitis
possible to change the menu language during the initialisation phase.
Youcanscrollthroughthelanguagechoicesbypressingthe[+]or[–]buttons.
Savethedesiredlanguagewiththe[P]button.
All texts / messages are subsequently displayed in the selected language.
DEUTSCH
ENGLISH
FRANCAIS
NEDERLANDS
DANSK
ESPANOL
POLSKI
CESKY
ITALIANO
SUOMI
SVENSKA
TÜRKÇE
NORSK
MAGYARUL
DEUTSCH
FINE-UP
Fine adjustment of the UP limit position in relation to the saved limit position
(UPSWITCH).
Only visible with electronic limit position system.
-250 – 250 0
FINE-DOWN Fine adjustment of the DOWN limit position in relation to the saved limit position
(DOWNSWITCH).
Only visible with electronic limit position system.
-250 – 250 0
INT POS UP Setting the switching point UP intermediate position (Sect. UP) in relation to the
saved limit position UP. Display as a negative value.
Only visible with electronic limit position system.
Automatic teach-in of the position:
Ô “7.5Settingtheintermediatepositionsoftheelectroniclimitpositionsystemvia
theLCDmonitor”
A (teaching)
-1–DOWNSWITCH
A
INT POS
CLOSED
Setting the switching point DOWN intermediate position (Sect. DOWN) in relation to
the saved limit position DOWN. Display as a positive value.
Only visible with electronic limit position system.
Automatic teach-in of the position:
Ô “7.5Settingtheintermediatepositionsoftheelectroniclimitpositionsystemvia
theLCDmonitor”
A (teaching)
1–UPSWITCH
A
OPEN TIME After opening, the door automatically travels in the DOWN direction after the set
value has passed.
Note:
Pressing the DOWN button during the open time starts the closing operation
immediately.
Pressing the UP or STOP button during the open time restarts the time.
If an automatic closing operation is interrupted by the closing edge protective device,
the open time is added to every new attempt. After 3 attempts, automatic closing is
cancelled.
OFF,
1 – 3600 seconds
OFF
START
WARN.
The start-up warning is implemented before every run. OFF,
1 – 10 seconds
OFF
FOREWAR-
NING TIME
The warning time is activated before automatic downward travel or closing through
pulse operation.
Note: This time is added to the start-up warning
OFF,
1 – 300 seconds
OFF