EN
Control CS 320 / Rev.D 1.01 – 53
11. Fault display and remedial measures
11.1 11.1 Fault display on the LCD monitorFault display on the LCD monitor
Fault / message Cause Rectication
System does not react. – No voltage present. – Check power supply for the drive and controller.
Door drives to the CLOSED limit
position upon actuation of the
OPEN button.
Door drives to the OPEN limit
position upon actuation of the
CLOSE button.
– Rotatingeldhasbeenincorrectlyconnected. – Checkrotatingeldandestablishrightrotatingeldif
necessary.
FAULT – X – internal software or hardware error. – RESET via circuit board button:
Ô “8.6RESETTINGthecontrollerwithoutLCDmonitor”
SAFETY CIRC. – The safety circuit is interrupted.
X3 / 1+2 Safety circuit controller
EMERGENCY STOP, slack rope
switch
X6 / 1+2 ON / OFF internal
X11 / 4+8 Safety circuit drive AWG
X2 / B1+B2 Safety circuit drive MEC
X3 / 3+4 Stop button external
X7 / 1+2 Stop button internal
– Check safety circuit, locate interruption and eliminate
problem.
ERROR STOP – An error has occurred at the safety input
(X4/11-12 - MOD2).
– Check all components at the safety input and replace if
necessary.
ERROR RUNTIME – The programed running time has been exceeded. – Check the path of the door and running time.
– Re-programme the running time if necessary.
ERROR AWG – Signal transmission between absolute value
encoder and controller is interrupted or faulty.
– Check cable and connector and replace if necessary.
TERMSWITCHFAIL – The door is located outside the programmed
limit position range.
– The limit positions are not yet programmed.
– Reset the door in the programmed range via the
emergency operation.
– First program the limit positions.
ERROR REVOLUTION – The power monitoring has triggered. – Check door for mechanical impairments.
ERROR DIRECTION – Thepresentrotatingeldisnotclockwise
rotating.
– Checkrotatingeldandchangeifnecessary.
Ô “7.1Checkingthedrive/traveldirection”
ERROR SKS CLOSE – Closing edge protective device 1 defective in
CLOSE direction –> (X4 / 5-8).
– Check closing edge protective devices and spiral cable.
ERROR SKS OPEN 2 – Closing edge protective device 2 defective in
OPEN direction –> (X4 / 11+12) input 2.
– Check closing edge protective devices and spiral cable.
ERROR STOP. 2 – Safety circuit 2 is interrupted.
Slipdoorswitch8.2kΩ
–> (X4 / 11+12) input 2.
– Check slip door switch.
ERROR SKS CLOSE 3 – Closing edge protective device 3 defective in
CLOSE direction –> (X20) Pluggable transmission
system RADIO channel 1.
– Check closing edge protective device.
– Check transmission system RADIO.
– Check setting of parameter SKS 3.