54 – Control CS 320 / Rev.D 1.01
Fault / message Cause Rectication
ERROR SKS OPEN 3 Closing edge protective device 3 defective in
OPEN direction –> (X20) Pluggable transmission
system RADIO channel 1.
Check closing edge protective device.
Check transmission system RADIO.
Check setting of parameter SKS 3.
ERROR STOP. 3 Safety circuit 3 is interrupted.
–> (X20) Pluggable transmission system RADIO
channel 1.
Check safety circuit.
Check transmission system RADIO.
ERROR SKS CLOSE 4 Closing edge protective device 4 defective in
CLOSE direction –> (X20) Pluggable
transmission system RADIO channel 2.
Check closing edge protective device.
Check transmission system RADIO.
Check setting of parameter SKS 4.
ERROR SKS OPEN 4 Closing edge protective device 4 defective in
OPEN direction –> (X20) Pluggable transmission
system RADIO channel 2.
Check closing edge protective device.
Check transmission system RADIO.
Check setting of parameter SKS 4.
ERROR STOP. 4 Safety circuit 4 is interrupted.
–> (X20) Pluggable transmission system RADIO
channel 2.
Check safety circuit.
Check transmission system RADIO.
ERROR SKS-TEST The test of the connected pressure wave strip
was unsuccessful.
CheckDWswitch,spiralcableandrubberprole.
Check DW-POINT setting.
The test of the transmission systems
RADIO1–4failed.
Check transmission system RADIO.
Check relay MOD setting for transmission system.
Ô “G. Functionsforexternalaccessories”onpage45
ERRORLIGHTBAR. The connected light barrier exhibits a permanent
fault.
–> (X4 / 1-4)
Check light barrier (function and alignment).
Check cabling.
ERRORLIGHTBAR.2 The connected light barrier exhibits a permanent
fault.
–> (X4 / 9+10) input 1
Check light barrier (function and alignment).
Check cabling.
ERROR LB TEST The test of the 2-wire light barrier failed. Check light barrier (function and alignment).
Check cabling.
ERROR STOP-TEST Thetestoftheslipdoorswitch(8.2kΩ)failed.
–> input 2
Check slip door switch.
ERROR TRAPIN The test of the trap-in protection (auxiliary
module) failed.
–> Relay MOD21
Check light barrier (function and alignment).
Check cabling.
ERROR CYLINDER The monitoring limit switch of the locking system
for threshold-free slip doors has not switched
within 10 seconds of the input of an OPEN
command.
Check limit switch of the cylinder.
ERROR MSBUS The communication between the controller and
connected MS-BUS module is interrupted.
Check cable and connectors and replace if necessary.