12. Technical data
12.1 12.1 Mechanical and electrical dataMechanical and electrical data
Housingdimensions: 215 x 275 x 190 mm
Installation: Vertically, on the wall;
Min.heightof1,100mm
Supply via
L1, L2, L3, N, PE: 400V/3~,50/60Hz
230V/3~,50/60Hz
L1, N, PE: 230V/1~,50/60Hz
Power input max. 2,200W
with supply 400V/3~
Fuse protection: 10 A K-characteristic
Controller internal
consumption:
max. 750 mA
Control voltage: 24 V DC, max. 500 mA; protected by
automatically resetting fuse for external sensors
Controller inputs: 24 V DC, all inputs are to be connected
potential-free.
Minimum signal duration for input controller
command >100 ms.
Controller outputs: 24 V DC, max. 500 mA.
Safety circuit /
emergency stop:
All inputs must be connected potential-free;
with an interruption of the safety chain, no
further electrical movement of the drive is
possible, even with dead man’s switching.
Safety strip input
(protection level C):
Performance Level C,
for electrical safety strips with
8.2kΩterminalresistanceandfordynamically
optical systems.
Light barrier
(Protection level D):
If the light barrier is used as a protection
system according to level D, its function must
be checked regularly and within 6 months as a
minimum.
If this is a self-testing system, this requirement
does not apply.
Safety input with
resistance evaluation
Performance Level C, cat.2
forsafety-relatedcomponentswith8.2kΩ
terminal resistance
Display (LCD): Only an original LCD monitor from
Marantec Legden may be used.
#91447 Standard
#121246 MS BUS
Relay outputs: If inductive loads are to be switched (e.g.
Additional relays or brakes), these must be
equipped with corresponding interference
suppression measures (e.g. Free-wheeling
diodes, varistors, RC elements). Work contact
potential-free;min.10mA;max.230VAC / 4A.
Contacts that have been used for power
switching can no longer be used for switching
low currents.
Temperature range: Operation: -10°C to +45°C
Storage: -25°C to +70°C
Humidity: Up to 80% non-condensing.
Vibrations: Low-vibration mounting, e. g. on a masonry
wall.
Protection grade IP 65
Weight approx. 1.8 kg