34 – Control CS 320 / Rev.D 1.01
Display Description
AUTOMATIC
TEACHINRUN
The run-time is taught automatically.
AUTOMATIC
OPENING
The door is currently in the opening phase.
AUTOMATIC
CLOSING
The door is currently in the closing phase.
AUTOMATIC
STANDBY POSITION
The door is currently in an intermediate position.
AUTOMATIC O
STANDBY POSITION
The door is in the UP limit position.
AUTOMATIC o
STANDBY POSITION
ThedoorisintheSect.UPposition(“intermediatepositionUP”parameter).
AUTOMATIC U
STANDBY POSITION
The door is in the DOWN limit position.
AUTOMATIC u
STANDBY POSITION
ThedoorisintheSect.DOWNposition(“intermediatepositionDOWN”parameter).
AUTOMATIC r
STANDBY POSITION
The door is in the reverse shut-off position.
AUTOMATIC
STOP
The command button STOP (cover keypad CS) was pressed for longer than 5 seconds.
AUTOMATIC
PERMANENT INPUT
When the power is switched off, an active signal (NO) is detected at the UP, DOWN, pulse or programmable
input 1 (with use of I/O BUS modules, also inputs 11-14 or 15-18).
This always constitutes an impermissible state. The cause is probably a defective component that must be
replaced.
Exception: The signal comes from a pluggable timer or the programmable input 1 if this is set as a timer
function(MOD4),orrealarmfunction(MOD5-9,13).
AUTOMATIC
CRASHSENSOR
The door system crash sensor has been activated (connection to X4/9-10, programmable input 1, MOD18).
A vehicle (e. G. forklift truck) has possibly driven into the closed door.
SERVICE
STANDBY POSITION
The pre-selected service interval has been reached.
Ifthe“Self-locking”parameterissettoMOD2-7orMOD9intheinputmenu,thedisplayswitchesfromAUTOMATICmodetoMANUAL.
Display Description
MANUAL
MAN. UP
The door is currently in the opening phase.
MANUAL
MAN. DOWN
The door is currently in the closing phase.
MANUAL
STANDBY POSITION
The door is currently in an intermediate position.
10. Functional overviews
10.1 Automatic mode

Table of Contents