Control CS 320 / Rev.D 1.01 – 43
10.3 10.3 Explanations of the relay modes:Explanations of the relay modes:
A. Trafc light functions
MOD Description
CLOSED limit
position
OPEN limit posi-
tion
Forewarning Door movement
MOD1 Redtrafclightinside1 ON / OFF
1
OFF
2
Flashing Illuminated
MOD2 Redtrafclightinside2 ON / OFF
1
OFF
2
Flashing Flashing
MOD3 Redtrafclightinside3 ON / OFF
1
OFF
2
Illuminated Illuminated
MOD18 Redtrafclightinside4 OFF OFF Flashing OFF
MOD23 Greentrafclightinside OFF Illuminated
2
OFF OFF
MOD44 Redtrafclight
inside + outside
OFF OFF OFF Flashing
3
MOD60 Redtrafclightoutside1 ON / OFF
1
OFF
2
Flashing Illuminated
MOD61 Redtrafclightoutside2 ON / OFF
1
OFF
2
Flashing Flashing
MOD62 Greentrafclight
4
OFF Illuminated
2
OFF OFF
1
depending on the parameter TL REST
2
With active two-way control: Depending on the UP command inside or outside
3
from intermediate position DOWN to DOWN, also after stop command. Only in CLOSE direction.
B. Position messages
MOD Description Remarks
MOD6 UP limit position The relay closes the contact when the door is in the OPEN limit position.
MOD7 DOWN limit position The relay closes the contact when the door is in the CLOSED limit position.
MOD8 Not OPEN limit position The relay closes the contact when the door is not in the OPEN limit position.
MOD9 Not CLOSED limit position The relay closes the contact when the door is not in the CLOSED limit position.
MOD10 Intermediate OPEN position (Sect.
OPEN)
The relay closes the contact when the door is in the intermediate OPEN position (Sect. OPEN).
MOD11 Intermediate CLOSED position
(Sect. CLOSED)
The relay closes the contact when the door is in the intermediate CLOSED position (Sect. CLOSED).
MOD12 Intermediate CLOSED position to
CLOSED limit position
The relay closes the contact when the door is in the range between the CLOSED limit position and the
intermediate CLOSED position (Sect. CLOSED).
MOD19 Intermediate OPEN position to
OPEN limit position
The relay closes the contact when the door is in the range between the OPEN limit position and the
intermediate OPEN position (Sect. OPEN).