18 – Control CS 320 / Rev.D 1.01 Control CS 320 / Rev.D 1.01 – 19
EN
For a precise description of the function and connection,
refer to the separate documentation for the week timer and
brake monitoring module.
Connection of the brake monitoring module
A
C
B
D
1
2
4
3
1
2
3
4
5
6
7
8
X5
M
X10
XB1
5.13 / 4
Legend:
A Brake monitoring module BWM 1
B Brakerectier
C Drive brake
D Brake power supply (AC)
NOTE:
If MOD14-16 (brake actuation) is set on relay 4, the mode for
the brake monitoring module is automatically set at input 3. If
a timer is used, this setting must be adapted to set the MOD
for the timer at input 3.
Optionally, input 3 can also be used for monitoring an
external load contactor and the drive brake.
The parameter INPUT 3 must then be set to MOD22.
Connection for monitoring an external load contactor
and drive brake (optional)
If the power of the door drive/frequency inverter used exceeds
the maximum load capacity of the internal contactor, an
external load contactor must be used.
In this case, it is possible to monitor the external load
contactor and drive brake with input 3 and therefore
guarantee safe operation.
13
NO
14
NO
53
NO
54
NC
13
NO
14
NO
53
NO
54
NC
13
NO
14
NO
+ 5V
GND
IN
X10
53
NO
54
NC
➞
5.13 / 5
B
A
C
Q1Q2
Legend:
A Brakerectier
B Drive brake
C Brake power supply (AC)
Q1 Mains contactor
Q2 Load contactor
The wiring preparation is carried out in the factory.