Display Meaning Condition
IMPULS Command button / input IMPULS
(X3 / 7+8)
ON: Button is actuated / input is active.
OFF: Button is not actuated / input is not active.
TIMER Week timer (pluggable) ON: Timer is active.
OFF: Timer is not active.
LIGHTBARR. Light barrier 1
(X4 / 1-4)
ON: Light barrier signal is OK.
OFF: Light beam interrupted or light barrier defective.
LIGHTBARR.2 Light barrier 2
Connection at input 1
(X4 / 9+10)
ON: Light barrier signal is OK.
OFF: Light beam interrupted or light barrier defective.
SAFETY CIRC. Safety circuit 1
Emergency stop systems of door system
ON: Safety circuit is closed.
OFF: Safety circuit is interrupted.
STOP Command button STOP (cover keypad) ON: Button is not actuated.
OFF: Button is actuated.
ROT FIELD Shows the currently set rolling direction
of the drive
RIGHT: Settingforarightrotatingeld.
LEFT: Settingforaleftrotatingeld.
CYCLE Door cycle counter Display of the door cycles that have run through:
1 x open + 1 x CLOSE = 1 cycle
Counting only takes place when the end switch-off points have each been reached.
SERVICE Service alarm function
Setting via parameter SERVICE and
PIN no. 2
OFF: Service display not active.
0 – 99999: Service display is active.
Display of the remaining door cycles up to the service message.
AWG Position information of the absolute
value encoder
Display of the currently transferred value.
C.STOP HALT/STOPcounter Shows how often the door was stopped. Either through activation of a safety device,
incaseofdirectdirectionreversalbyaruncommandorbyadirectSTOP/HALT
command.
C.OPENED Counter for top limit position Shows how often the top limit position was approached.
C.O.BTN Counter for OPEN commands Number of all incoming OPEN commands through command devices, sensors and
safety devices (e. g. light barrier).
ERROR…
COUNT
CYCLE
Controller error memory.
The error messages of the controller
can be read out here with information
about frequency and cycle.
Usethe[+]and[-]keysontheLCD
monitor to scroll through the list of
various error messages.
Ô “11.1FaultdisplayontheLCD
monitor”
Deletion of the error memory:
Pressthebuttons[+]and[–]
simultaneously for approx. 2 seconds.
Each error message must be individually
deleted.
The display changes in 2-second intervals between
– the fault description,
– the frequency of occurrence, and
– the information on which cycle the fault arose most recently.