80
ZENIT
TECHNICAL DATA
Data Acquisition
ZENIT ZENIT F ZENIT FP
Mode FIRST : Classification window stops at selected length (10–1000 km)
* * *
Mode LAST
: Floating window. Selected length (10–1000 km)
* * *
Mode CONE:
Group: Floating window. Selected length (10–1000 km)
Spindle: The data are cleared when the length is reached
* * *
Clearing of Synthetic Foreign Matter (PP, PE, etc.)
ZENIT ZENIT F ZENIT FP
Foreign matters PP PE Limit for electrical charge (sensitivity) 0.5 to 9.9
*
Reference length TK YM ZENIT FP C 0.5 cm to 4.0 cm
*
Reference length TK YM ZENIT FP C P2 1.0 cm to 8.0 cm
*
Yarn Monitoring
ZENIT ZENIT F ZENIT FP
Yarn Count Channel (Cops Mix-up)
Diameter deviation ±3% to ±44%
* * *
Reference length 10 m to 50 m
* * *
Short Count Channel
Diameter deviation ±3% to ±44%
* * *
Reference length 1 m to 32 m
* * *
Cluster (Fault Accumulations)
Diameter Short Cluster 1.10 to 4.00
* * *
Long Cluster 1.04 to 2.00
* * *
Thin Cluster -6% to -60%
* * *
Length Short Cluster 1.0 cm to 10 cm
* * *
Long Cluster 6.0 cm to 200 cm
* * *
Thin Cluster 2.0 cm to 200 cm
* * *
Observation length 0.1 m to 80 m
* * *
Maximum fault number relative to the set observation length 1 to 9999
* * *
F Cluster (Accumulations of Foreign Matter)
Detection according to 64 SIRO classes each dark and bright
* *
Observation length 0.1 m to 80 m
* *
Maximum fault number relative to the set observation length 1 to 9999
* *
Repetitions
Number of repetitions 0 to 9
* * *
Alarms
Automatic locking when reaching the limits of yarn fault cuts during start-up
* * *
Automatic spindle locking when exceeding set number of yarn count cuts
* * *
Automatic spindle locking when exceeding set number of fault cluster cut
* * *
Automatic locking when reaching the set limits of foreign matter cuts during start-up
* *
Automatic locking when reaching the set limits of foreign matter cluster cuts
* *