TECHNICAL DATA
LabPack (Option)
ZENIT ZENIT F ZENIT FP
Surface Index (SFI)
Online quality data monitoring per spindle and group
* * *
Surface Index Channel (SFI/D)
Floating or constant reference 5.0 to 25.0
* * *
Limits +/– (maximum deviation from reference value) ±5% to ±40%
* * *
Number of repetitions 0 to 5
* * *
Check length
80 m
* * *
Automatic spindle locking when exceeding set number of Surface Index (SFI/D) channel cuts and
repetitions respectively
* * *
Variable CV Channel (VCV)
Limite +/- (maximum deviation from mean value) ±5% to ±100% * * *
Number of repetitions 0 to 5
* * *
Check length 1 m to 50 m * * *
Automatic spindle locking when exceeding set number of Variable CV Channel (VCV) channel cuts and
repetitions respectively
* * *
Imperfections
Number of frequent yarn faults according to diameter limit per 1000 m
Neps Diameter limit >1.80
* * *
Thick Diameter limit >1.30 to <1.80
* * *
Thin Diameter limit <0.75
* * *
Number per meter
Small Positive deviation: Diameter limit 1.20 to 1.30
* * *
Negative deviation: Diameter limit 0.80 to 0.75
* * *
Number of frequent yarn faults according to length limit per 1000 m
4 yarn fault classes length-referred in the range of 2 cm to 70 cm
* * *
Positive and negative deviations with diameter limits >1.20 to <0.80
* * *
Installation Monitoring
ZENIT ZENIT F ZENIT FP
Alarms
4 yarn fault classes length-referred in the range of
* * *
Positive and negative deviations with diameter limits
* * *
Central Data Collection
ZENIT ZENIT F ZENIT FP
Data Collection with Loepfe MillMaster
Central units can be linked with Ethernet
* * *
Remote control of clearer parameter
* * *
Central collection of quality data up to spindle level
* * *
Central collection of production data up to spindle level
* * *