5 -25
5-10. Every 1200 hour or 1 year check
Cover
Primary
element
Safety filter
element
Evacuator valve
(1) Replacing Air cleaner element
(Dry type)
z If the air-cleaner service indicator in the
instrument panel is turned on, make sure to
check and replace the filter element regardless
of recommended service intervals in this
maintenance chart.
z Remove the cover and pull the primary element
straight out, ensuring the safety filter element
remains in place.
z Clean the inside of the air cleaner housing using
a clean damp cloth, taking care not to damage
the safety element.
z Check if there is any damage inside filter element
by using a light. If finding tiny crack or small
holes in the filter element or the gasket is
damaged, change it with a new one.
z Insert the filter element by pushing it deeply into the filter housing.
z Remove the dust of the evacuator valve and clean the inside of the cover.
z Assemble the cover with the evacuator valve placed downward.
▶ Do not start the engine or close the hood if the filter element is not assembled..
Notice