RadioRA® Setup Guide4-5
Returning Components to Default Factory Settings
Section 4 - Troubleshooting
Master Controls
Returning a Master Control to Default Factory Settings will permanently delete all current programming
information. Do not do this unless you are sure that it is necessary. For more information call the
Lutron Technical Support Center.
Step 1 Begin returning to Default
Factory Settings
Step 2 Complete returning to Default
Factory Settings
While the 1st, 3rd, and 5th LED are
flashing, press and hold the 2nd and 4th
buttons in the right most column until all the
LEDs flash.
ALL ON
ALL OFF
ALL ON
ALL OFF
All LEDs will turn OFF, indicating that the
Master Control has been returned to Default
Factory Settings.
ALL ON
ALL OFF
Ensure that the ACTIVATE REPEATER LED or
ACTIVATE CONTROLS LED on any Repeater
is NOT ON before proceeding. If either LED is
ON, press the corresponding button until it's
LED turns OFF (approximately 3 seconds).
Press and hold the 1st, 3rd and 5th buttons in
the right most column until the corresponding
LEDs begin to flash (approximately 3
seconds).
ALL ON
ALL OFF
Wall Master Tabletop Master
OR
ALL ON
ALL OFF
LEDs will flash for only 3 seconds.

Other manuals for Lutron Electronics RadioRA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lutron Electronics RadioRA and is the answer not in the manual?

Lutron Electronics RadioRA Specifications

General IconGeneral
BrandLutron Electronics
ModelRadioRA
CategoryControl Systems
LanguageEnglish

Related product manuals