RadioRA® Setup Guide3-5
Adding a Switch Closure Interface
Section 3 - Expanding Your System
Activating a Switch Closure Interface
The Switch Closure Interface is a special type of Master Control. Therefore, the System can have a maximum of
12 Master Controls plus a Switch Closure Interface. For every 1 Master Control NOT used, 1 Switch Closure
Interface may be used in its place.
Step 2 Activate Switch Closure
Interface
If a Switch Closure Interface fails to respond as
described above, consult the Troubleshooting
Guide, Section
XI.
• All input LEDs will flutter, then
• The Flash LED and Input 1 LED will
alternately flash.
Step 1 Begin Switch Closure
Interface activation
Press and hold the ACTIVATE CONTROLS
button on
any
Repeater until the green
ACTIVATE CONTROLS LED turns ON
(approximately 3 seconds).
MAIN
REPEATER
REPEATER
CONTROLS
ACTIVATE
BEEP
FLASH
VERIFY
AUXILIARY
The green ACTIVATE CONTROLS LED on
ALL
Repeaters will turn ON.
MAIN
REPEATER
REPEATER
CONTROLS
ACTIVATE
BEEP
FLASH
VERIFY
AUXILIARY
Press any button.
u
e
or opera
ng
ns
ruc
ons.
For additional assistance call the
Lutron Technical Assistance
Hotline:
1-800-523-9466
FCC ID JPZ0005
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference and (2) This device must accept any
interference received including interference that may cause undesired operation.
Patents Pending
18V
AC IN
Full
Flash
Input 1
Input 2
Input 3
Input 4
Input 5
Common
.
For additional assistance call the
Lutron Technical Assistance
Hotline:
1-800-523-9466
FCC ID JPZ0005
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference and (2) This device must accept any
interference received including interference that may cause undesired operation.
Patents Pending
18V
AC IN
Full
Flash
Input 1
Input 2
Input 3
Input 4
Input 5
Common
Input 4 LED will remain ON when the Switch
Closure Interface has been activated.
The Switch Closure Interface has a 15 second
delay after applying power. During this time the
Power LED will blink. When the Power LED
stays ON, the unit is ready for operation.