Bank < and > Buttons
To edit the functionality of the Bank < or > buttons when in DAW Edit Mode, press and hold
the SHIFT button and press the BANK < or BANK > button. You can scroll through the
available parameter values using the Encoder. Select what parameter you would like to edit by
pressing the Encoder.
Channel: The Bank < or > button will send its messages over this channel. Select the global
channel (Global), or a specific channel (Channel 116).
Available Values: Global, 1-16
Message:
Mode: This will specify what message will be sent when the Bank < or > button is
pressed.
o CC: When set to CC, the Bank < or > button will send standard MIDI CC messages
to your DAW.
o Program: The Bank < or > button will send its MIDI messages using the selected
Program number and MSB and LSB values.
o Mackie: When set to Mackie Control, you can use the Bank < or > button with a
DAW that responds to Mackie Control mode.
o Mackie/HUI: When set to Mackie/HUI, you can use the Bank < or > button with a
DAW that responds to HUI mode.
CC: Selects the MIDI CC value that will be sent when the Bank < or > button is pressed.
Down: The Bank < or > button will send this CC value when you press it.
Up: The Bank < or > button will send this CC value when you release it.
Program: The Bank < or > button will send this program number when you press it.
MSB: The Bank < or > button will send this Bank MSB (Most Significant Byte) number
when you press it.
LSB: The Bank < or > button will send this Bank LSB (Least Significant Byte) number
when you press it.