Maintenance
54
IDM 510-006-5
English language Operation and maintenance manual
Alarm message table
no. Type of failure Remedy
Machine alarms
01
Sensor does not detect the shifting of
machine.
- Check the connections and/or the position of sensor.
- Press control N to silence the alarm.
02
(Lower and upper) sensors do not detect the
end of stroke of the reel holding carriage.
- Check the connections and/or the position of sensors.
- Press control N to silence the alarm.
05
The carriage drive chain is not correctly
tensioned.
- Make sure that the reel holding carriage can move freely and without
obstacles.
- Check the connections and/or the position of the photocells.
- Press control N to silence the alarm.
- Control L lights up.
- Press control L.
- Reel holding carriage moves upwards and then it moves downwards
again in order to phase the operating units.
06
The photocell does not detect any load to be
wrapped.
- Make sure that the load to be wrapped is properly positioned.
- Check the connections and/or the position of the photocell.
- Press control N to silence the alarm.
08
The lm reel is exhausted (Only for reel
holding carriages of type LP).
- Replace reel (See “Film Coil Feeding”).
Machine shifting inverter alarms
10
The inverter parameters are not properly set
up.
- Contact the Manufacturer’s Technical Assistance Service.
11
The activation of the inverter electric power is
not correctly enabled.
- Contact the Manufacturer’s Technical Assistance Service.
12
The electric motor is damaged due to a short
circuit.
- Contact the Manufacturer’s Technical Assistance Service.
13
The heat protection is damaged because of
the overheating of the electric motor.
- Let the motor cool down.
- Press control N or deactivate and re-activate power (even more than
once) to silence the alarm.
- Replace electronic board if the alarm persists.
17
Communication was interrupted because of an
internal error.
- Contact the Manufacturer’s Technical Assistance Service.

Table of Contents