EasyManua.ls Logo

MAHA LPS 3000 - Calculate Engine Factor Fm

MAHA LPS 3000
115 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BA052301-en 39
2.9.6 Calculate Engine Factor fm
In most cases fm = 0.3 applies but this value can be changed.
The following equations are used:
Engine factor fm based on ISO 1585:
652,37
r
q
14,1.036,0 =
r
q
fm
2,37
r
q
2,0=fm
65
r
q
2,1=fm
Engine factor fm based on EWG 80/1269, SAE J1349 and JIS D1001:
6540
r
q
14,1.036,0 =
r
q
fm
40
r
q
3,0=fm
65
r
q
2,1=fm
Pressure behavior of the supercharging:
E
L
P
P
r =
Specific fuel consumption based on SAE J1349:
4-Takt Motoren
nD
F
q
= .120000
2-Takt Motoren
nD
F
q
= .60000
with
fm Engine factor
r Pressure behavior of the supercharging
q Specific fuel consumption based on SAE J1349
p
L
Absolute boost pressure
p
E
Absolute pressure in front of the compressor
F Fuel flow (mg/s)
D Cubic capacity volume
n Engine RPM

Table of Contents

Related product manuals