2.9.6 Calculate Engine Factor fm
In most cases fm = 0.3 applies but this value can be changed.
The following equations are used:
Engine factor fm based on ISO 1585:
652,37
r
q
14,1.036,0 =
r
q
fm
2,37
r
q
2,0=fm
65
r
q
2,1=fm
Engine factor fm based on EWG 80/1269, SAE J1349 and JIS D1001:
6540
r
q
14,1.036,0 =
r
q
fm
40
r
q
3,0=fm
65
r
q
2,1=fm
Pressure behavior of the supercharging:
E
L
P
P
r =
Specific fuel consumption based on SAE J1349:
4-Takt Motoren
nD
F
q
= .120000
2-Takt Motoren
nD
F
q
= .60000
with
fm Engine factor
r Pressure behavior of the supercharging
q Specific fuel consumption based on SAE J1349
p
L
Absolute boost pressure
p
E
Absolute pressure in front of the compressor
F Fuel flow (mg/s)
D Cubic capacity volume
n Engine RPM