Maintenance work on the carrier
7.3 Engine
7 - 24 3 302 649 en Maintenance manual
GMK4090
07.12.2017
• Familiarise yourself with the correct operation of the frequency measur-
ing instrument;
à Separate operating manual.
• Switch the frequency measuring instru-
ment (1) on – it is now ready for acoustic
measurement.
• Hold the measuring head (3) over the
V-belt (4).
• Strike the V-belt (4) with an object (tool) so
that it vibrates.
• On the display (2), read the measured value:
new V-belt: 78.2 Hz;
run-in V-belt: 68.6 Hz.
• If necessary, correct the pre-tension until the specified measured value is
achieved.