Maintenance work on the carrier
7.12 Suspension
07.12.2017
Maintenance manual 3 302 649 en 7 - 81
GMK4090
7.12.4 Pressure accumulator – checking the gas pressure
The gas pressure must be checked every 3000 operating hours, but in any
case no less frequently than every 12 months.
The suspension has integrated pressure accu-
mulators (1) that contain nitrogen.
The filling pressure at 20 °C (68 °F) is 50 bar
(725 psi).
• Have the filling pressure checked, and if nec-
essary corrected, by
Manitowoc Crane Care or
an authorised GROVE dealer or an author-
ised specialist workshop.
M 12
G
Risk of accidents due to incorrect inspection
The gas pressure test must be carried out only by an authorised official
inspector of pressure tanks or under his/her supervision or instructions.