Maintenance work on the superstructure
8.13 Air conditioning system
8 - 78 3 302 649 en Maintenance manual
GMK4090
07.12.2017
8.13.5 Changing the pollen filter
Reducing
the interval
• Under difficult operating conditions – at extremely sandy or dusty loca-
tions – you must change the filter earlier than normal.
Spare parts
and tools
Prerequisites – The engine is not running and is secured against unauthorised use;
à p. 2 - 3.
Changing
• Open the cover (1).
• Remove the filter (2) from the housing and
clean the housing with a cloth.
• Insert a new filter.
• Fasten the cover (1).
M 12
Designation Quantity GROVE part no.
Filter 1 04163620