Maintenance work on the superstructure
8.6 Hydraulic system
8 - 36 3 302 649 en Maintenance manual
GMK4090
07.12.2017
8.6.6 Changing the ventilation filter
Spare parts
and tools
Prerequisites – The engine is not running and is secured against unauthorised use;
à p. 2 - 3.
• Remove the cap (2).
• Change the filter (3) and screw on the cap
tightly.
• Reset the display by depressing the pin (1)
on the housing.
M 12
Designation Quantity GROVE part no.
Filter 1 03134932
O
Risk of damage to the environment from filter residues
Store used hydraulic oil filter inserts in suitable receptacles and have them
disposed of properly by qualified personnel.