Maintenance work on the superstructure
8.6 Hydraulic system
8 - 34 3 302 649 en Maintenance manual
GMK4090
07.12.2017
8.6.5 Cleaning the magnetic rods
Spare parts
and tools
– Receptacle, about 5 l (1.5 gal); à p. 2 - 4.
Prerequisites – The truck crane must be standing on a level surface.
– The engine is not running and is secured against unauthorised use;
à p. 2 - 3.
– During the first 100 operating hours: Clean the magnetic rods weekly.
M 3
Designation Quantity GROVE part no.
For oil filter 1:
Filter 1 04156358
Packing set 1 04165792
O
Risk of environmental damage due to leaking consumables
Always let consumables drain into suitable receptacles. Wipe up any
consumables that escape.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.