Maintenance work on the carrier
7.16 Central lubrication system
7 - 112 3 302 649 en Maintenance manual
GMK4090
07.12.2017
7.16.3 Triggering intermediate lubrication
Intermediate lubrication should be activated:
– after high pressure cleaning,
– to check the lubrication system at all lubricating points.
• Switch on the ignition.
• Press the button (1) once.
An intermediate lubrication cycle will be trig-
gered which lasts about two minutes. Check
that grease is escaping at all lubricating points
(steering arms on the 1st, 2nd, 3rd, and 4th
axle lines).
• Switch off the ignition and remove any
excess grease.