Maintenance work on the superstructure
8.6 Hydraulic system
8 - 40 3 302 649 en Maintenance manual
GMK4090
07.12.2017
Changing oil
filter 1
• Remove the cover (1).
• Remove the cap (2) and pull out the hydrau-
lic oil filter.
• Place the filter in a receptacle.
• Remove the filter (4) from the filter cage (5).
• Clean the filter cage (5) and insert a new fil-
ter (4).
• Clean the magnetic rods (3).
• Replace any damaged parts, where
necessary.
• Assemble the filter (3) and insert it.
• Replace the cover gasket if necessary.
• Fasten the lid (2).
• Attach the cover (1).
O
Risk of environmental damage due to leaking consumables
Always let consumables drain into suitable receptacles. Wipe up any
consumables that escape.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.
S
Risk of damage to the hydraulic system
Large amounts of metal particles are a sign of damage in the hydraulic
system.
Have the hydraulic system checked by Manitowoc Crane Care or an
authorised GROVE dealer or your qualified repair crew.

Table of Contents

Other manuals for Manitowoc GROVE GMK4090

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK4090 and is the answer not in the manual?

Manitowoc GROVE GMK4090 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK4090
CategoryConstruction Equipment
LanguageEnglish

Related product manuals