RT9130E-2 SERVICE MANUAL HYDRAULIC SYSTEM
2
Checking Charge Air Cooler Motor Control
Valve – For Tier 3 ONLY
1. Install pressure check diagnostic quick disconnect
(Parker PD240) with gauge onto test nipple at Charge
Air Cooler Motor Control Valve
2. With engine at full RPM, unplug harness connection on
control solenoid to turn cooler on. Adjust relief valve to
obtain a reading of 1000 ± 50 PSI (6.9 ± 0.4 MPa). Turn
in to raise, out to lower.
3. Remove pressure gauge and plug harness connection
back into control solenoid.Cylinders