EasyManuals Logo

Manitowoc Grove RT9130E-2 Service And Maintenance Manual

Manitowoc Grove RT9130E-2
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #329 background imageLoading...
Page #329 background image
Grove Published 11-22-2016, Control # 345-12 9-9
RT9130E-2 SERVICE MANUAL LUBRICATION
9
Item
Lube Point
Description
Figure
No.
Approved
Lubricant
Lube
Capacity
Lube Interval Application
Axles
11 Differentials Figure 9-2
GL-5
Extended
Service Interval
Gear Lubricant
6829012964
72 pints
(34 l)
Check level every
500 hours or 3
months
Drain and fill every
4000 hours or 2
years
Fill to bottom of hole
in housing on the
steer cylinder side
NOTE: Lube level close enough to the hole to be seen or touched is not sufficient. It must be level with the hole.
When checking lube level, also check and clean housing breathers.
CAUTION: Use of non-approved lubricant may damage components and/or invalidate published lubricant intervals.
CAUTION: If the makeup amount is substantially more than 0.23 liter (0.5 pint), check for leaks.
12
Planetary Hubs
and Wheel
Bearings
Figure 9-2
GL-5
Extended
Service Interval
Gear Lubricant
6829012964
30 pints
(14 l)
Check level every
500 hours or 3
months
Drain and fill every
4000 hours or 2
years
Fill to the bottom of
the level hole in the
housing with the fill
plug and the oil level
mark horizontal.
CAUTION: Use of non-approved lubricant may damage components and/or invalidate published lubricant intervals.

Table of Contents

Other manuals for Manitowoc Grove RT9130E-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT9130E-2 and is the answer not in the manual?

Manitowoc Grove RT9130E-2 Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT9130E-2
CategoryConstruction Equipment
LanguageEnglish

Related product manuals