EasyManua.ls Logo

Mar Cor Purification MILLENIUM HX - TDS;µS Value High

Mar Cor Purification MILLENIUM HX
158 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Millenium HX RO System
3030226 Rev. D 6-11 Troubleshooting
6.14 TDS/µS Value High
The overall membrane performance can be affected by a number of factors. Poor
rejection performance, as well as, high TDS/µS can result from fouled membranes, low
pump pressure, inadequate waste flow, or RO feed water problems. The recommended
first step for any ‘membrane performance’ question is to confirm the rejection
percentage and product TDS/µS with a hand-held meter. If the product water quality is
poor, investigate the membrane. However, if the water quality tests ‘normal’,
investigate the monitoring circuits.
1. Disinfectant or cleaner left in RO unit.
a. Check for presence of disinfectant or cleaner; rinse as necessary.
2. Waste flow too low.
a. Measure and compare to original data.
3. Product flow too high.
a. See Section 6.11.
4. Membrane scaled or fouled.
a. Verify condition of softener pretreatment equipment.
b. See membrane cleaning procedure in this manual.
5. Erroneous meter readout.
a. Verify water quality with independent meter.
b. TDS/µS water probe wire disconnected or loose.
c. Verify incoming voltage.
6. Membrane failure.
a. Replace membrane.
7. Change in RO feed water TDS/µS.
a. Verify feed and product water quality with independent meter.
b. Communicate with municipal water plant.
c. Softener problem, rinsing out high levels of salt.
8. Normal membrane rejection decline (over time).
a. Perform AAMI / CSA water lab analysis.
1. Replace membrane if indicated by analysis.

Table of Contents

Related product manuals