Models ESM303 & ESM303H Test Stands User’s Guide
16
4.3.2 Dwell times (HI / R DWELL and LO / L DWELL)
This setting corresponds to the amount of time, in seconds, for which the crosshead stops at the limit
during a cycle sequence. Individually set dwell times can be applied to the upper and lower (or right and
left) limits.
Note:
The dwell time setting is unavailable for an auto return sequence.
Default setting: 0 (no dwell time)
Available settings: 0 9999.9
Label
Description
+
Increases dwell time in increments of .1. Holding down + will increment at an
increasingly faster rate. If 9999.9 is reached the next number will be 0 and
continue incrementing.
Decreases dwell time in increments of .1. Holding down will decrement at
an increasingly faster rate. If 0 is reached the next number will be 9999.9
and continue decrementing.
ENTR
Returns to the Test Function Setup menu
ESC
Exits the function without saving changes
4.4 Travel limits (HI LIMIT / RIGHT LM and LO LIMIT / LEFT LM)
Travel limits may be programmed as specified distances, either as upper and lower limits, or right and left
limits. The crosshead stops when the distance limits have been reached.
Default settings: Upper / Right: +20.000 in, Lower / Left: -20.000 in
Available settings: From -20.000 to +20.000 in
Label
Description
+
Increases the number of cycles in increments of 1. Holding down +
will increment at an increasingly faster rate. If 99999 is reached
the next number will be 00000 and continue incrementing.
Decreases the number of cycles in increments of 1. Holding down
will decrement at an increasingly faster rate. If 00000 is reached
the next number will be 99999 and continue decrementing.
Press and hold
+ and
simultaneously
If pressed and held for 2 seconds or longer the number of cycles
will change to 0.
ENTR
Returns to the Test Function Setup menu