Rad-97 Product Description, Features and Indications for Use
www.masimo.com 11 Masimo
intended to be used in conjunction with additional methods of assessing clinical signs and
symptoms.
The optional Nomoline Capnography product family is intended to be connected to other
medical backboard devices for monitoring of breath rate and CO
2
. The Nomoline
Capnography product family is intended to be connected to a patient breathing circuit for
monitoring of inspired/expired gases during anesthesia, recovery and respiratory care. The
environment is the operating suite, intensive care unit and patient room. The intended
patient population is adult, pediatric and infant patients.
The optional non-invasive blood pressure (NIBP) module is indicated for the noninvasive
measurement of arterial blood pressure. The NIBP module is designed to measure blood
pressure for patient population described in the following table:
Patient Population Approximate Age Range
Newborn (neonate) Birth to 1 month of age
Infant 1 month to 2 years of age
Child 2 to 12 years of age
Adolescent 12-21 years of age
Adult 21 years of age and older
Contraindications
The Rad-97 is not intended for use as an apnea monitor.

Table of Contents

Other manuals for Masimo Rad-97

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Masimo Rad-97 and is the answer not in the manual?

Masimo Rad-97 Specifications

General IconGeneral
Display Size7 inches
SpO2 Accuracy±2% (70-100%)
Pulse Rate Accuracy±3 bpm
Perfusion Index Range0.02% to 20%
Pleth Variability Index Range0% to 100%
SpO2 Range0% to 100%
SpHb Range0 to 25 g/dL
SpCO Range0% to 40%
Battery TypeRechargeable lithium-ion
Operating Temperature5°C to 40°C (41°F to 104°F)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Humidity Range10% to 95% non-condensing
DisplayColor touchscreen
ConnectivityWi-Fi, Ethernet, Bluetooth
Power Supply100–240 VAC, 50–60 Hz
Battery LifeApproximately 4 hours
MeasurementsSpO2, Pulse Rate, Perfusion Index, Pleth Variability Index, SpHb, SpOC, SpMet, SpCO
Pulse Rate Range25 to 240 bpm
HbCO Range0-99%
MetHb Range0-99%
SpMet Range0-99%
Data StorageInternal memory
AlarmsAudible and visual alarms for all parameters