Rad-97 Safety Information, Warnings and Cautions
www.masimo.com 17 Masimo
Hemoglobinopathies (qualitative defects including sickle cell) and Hemoglobin
synthesis disorders (quantitative defects such as Thalassemias).
Extremely elevated hemoglobin levels.
Low arterial perfusion.
Low arterial oxygen saturation levels including altitude induced hypoxemia.
Motion induced artifact.
Severe anemia.
WARNING: SpCO readings may not be provided if there are Low arterial oxygen saturation
levels or elevated methemoglobin levels.
WARNING: Inaccurate SpMet readings may be caused by:
Elevated carboxyhemoglobin levels in the range of > 3%.
Hemoglobinopathies (qualitative defects including sickle cell) and Hemoglobin
synthesis disorders (quantitative defects such as Thalassemias).
Extremely elevated hemoglobin levels.
Low arterial perfusion.
Low arterial oxygen saturation levels including altitude induced hypoxemia.
Motion induced artifact.
Physiological conditions that can significantly shift the oxygen disassociation
curve.
Severe anemia.
WARNING: Inaccurate RRa measurements may be caused by:
Improper sensor application or use of use of incorrect sensor.
Abnormal pulse rhythms due to physiological conditions or induced through
external factors (e.g. Cardiac arrhythmias, intra-aortic balloon, etc.).
Motion artifact.
Excessive ambient or environmental noise.
WARNING: Inaccurate RRp readings may be caused by:
Low arterial perfusion.
Motion induced artifact.
Severe anemia.
WARNING: Inaccurate ORi readings may be caused by:
Low arterial perfusion.
Motion induced artifact.
Elevated COHb and/or MetHb levels.
Hemoglobinopathies (qualitative defects including sickle cell) and Hemoglobin
synthesis disorders (Quantitative defects such as Thalassemias).

Table of Contents

Other manuals for Masimo Rad-97

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Masimo Rad-97 and is the answer not in the manual?

Masimo Rad-97 Specifications

General IconGeneral
Display Size7 inches
SpO2 Accuracy±2% (70-100%)
Pulse Rate Accuracy±3 bpm
Perfusion Index Range0.02% to 20%
Pleth Variability Index Range0% to 100%
SpO2 Range0% to 100%
SpHb Range0 to 25 g/dL
SpCO Range0% to 40%
Battery TypeRechargeable lithium-ion
Operating Temperature5°C to 40°C (41°F to 104°F)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Humidity Range10% to 95% non-condensing
DisplayColor touchscreen
ConnectivityWi-Fi, Ethernet, Bluetooth
Power Supply100–240 VAC, 50–60 Hz
Battery LifeApproximately 4 hours
MeasurementsSpO2, Pulse Rate, Perfusion Index, Pleth Variability Index, SpHb, SpOC, SpMet, SpCO
Pulse Rate Range25 to 240 bpm
HbCO Range0-99%
MetHb Range0-99%
SpMet Range0-99%
Data StorageInternal memory
AlarmsAudible and visual alarms for all parameters