LUTValueAll - - - -
Accesses all the LUT coefficients in a
single access without using individual
LUTIndex.
mvLUTType - - - Direct
Describes the type of LUT used.
Direct: The user can define an output value
for each input value of the LUT.
mvLUTInputData - - - Gray
Describes the data the LUT is operating on
Gray: The LUT is operating on gray data
mvLUTMapping - - - map_12To9
Describes the mapping of the LUT
map_12To9: The LUT maps 12 bit input
data to 9 bit output data.
Feature Name Min Max Inc
Valid
Values
Documentation
TestControl A category for Test Control features.
TestPendingAck 0 INT_MAX 1 -
Tests the device's pending
acknowledge feature. When this
feature is written, the device waits a
time period corresponding to the
value of TestPendingAck before
acknowledging the write. (ms)
TestEventGenerate@i - - - - Generates a Test Event.
Feature Name Min Max Inc
Valid
Values
Documentation
TransportLayerControl
Category that contains the
transport Layer control
features.
PayloadSize INT_MIN INT_MAX 1 -
Provides the number of
bytes transferred for each
image or chunk on the
stream channel. This
includes any end-of-line,
end-of-frame statistics or
other stamp data. This is the
total size of data payload for
a data block.
mvU3VPHYErrorCount 0 INT64_MAX 1 -
Counts the number of errors
on the PHY interface.
mvU3VLNKErrorCount 0 INT64_MAX 1 -
Counts the number of errors
on the USB3 link.
20 Appendix A.1 Pregius CMOS specific camera / sensor data
1094