21.7.3.3 Frame rate calculator
Frame rate calculator
Mode:
Overlapping exposure and readout (default)
Exposure and readout without overlapping
Pixel clock: 81.25 MHz
Image width: pixels
Image height: pixels
Exposure time: us
Frame rate (max): 1/s
ExposureTime > FrameTime
Note:
The maximum duration of the signal ExposureActive used in Counter, Timer, or as digital
output signal is limited to 207ms (80 MHz pixel clock). This limit also applies to the chunk
data parameter ChunkExposureTime. It does not matter which exposure time is set, the
value of this parameter will always be below or equal to 207ms (80 MHz pixel clock).
ExposureEndEvents are generated with the help of this signal, too and for this reason they
have too small timestamps above this limit.
21.7.4 Device Feature And Property List
21.7.4.1 Gray scale version
Feature
Name
Min Max Inc
Valid
Values
Documentation
ProductFeatures
This list has been created with driver version '2.17.3'
and Firmware version '2.14.488.0'. This does NOT
imply that all these features will only be available
since these versions. They might be available in
previous ones as well.
Feature Name Min Max Inc
Valid
Values
Documentation
Camera
This list contains features to
control the device
ImageRequestTimeout_ms
0
ms
INT_MAX
1
ms
-
Defines the timeout for the
request in ms. Once the
timeout has elapsed the
request object is returned to
the user even if no data has
been captured into it. A
timeout of 0 never elapses.
21 Appendix A.2 CMOS specific camera / sensor data
1819